FROM: Robert Thompson, General Manager
Originator: Riaz Moinuddin, Director of Operations & Maintenance
SUBJECT:
title
PLANT NO. 1 REPLACEMENT GEARBOX FOR TRICKLING FILTER CLARIFIER 1
end
GENERAL MANAGER'S RECOMMENDATION
recommendation
RECOMMENDATION:
A. Approve a Sole Source Purchase Order to Ovivo USA, LLC, for the procurement of one Ovivo C80 clarifier drive unit for Trickling Filter Clarifier 1, for a total amount not to exceed $159,653, plus applicable sales tax; and
B. Approve a contingency of $15,965 (10%).
body
BACKGROUND
Orange County Sanitation District (OC San) Plant No. 1 operates two 145-foot-diameter Trickling Filter Clarifiers. Trickling filter clarifiers are sedimentation tanks downstream of a trickling filter to remove settleable solids and sloughed biological growth. These two clarifiers provide secondary treatment for approximately 30 million gallons per day (MGD) of wastewater. Secondary effluent is conveyed to the Groundwater Replenishment System or discharged through the ocean outfall. Reliable clarifier operation is essential to maintain treatment capacity and regulatory compliance.
RELEVANT STANDARDS
24/7/365 Treatment plant reliability
Protect OC San Assets
Maintain a proactive asset management program
PROBLEM
A recent inspection identified a leak in Trickling Filter Clarifier 1 C80 drive unit (a high-torque motorized gearbox assembly that slowly rotates sludge collector rake arms to sweep settled biomass and sloughed biofilm for removal) requiring a complete rebuild or replacement. Failure of the drive unit could render the clarifier inoperable, reducing secondary treatment capacity and affecting process reliability.
PROPOSED SOLUTION
Procure a new C80 clarifier drive unit for Plant No. 1’s Trickling Filter Clarifier from Ovivo USA, LLC to maintain asset reliability and minimize process downtime.
TIMING CONCERNS
The replacement drive unit has a 22-week lead time. Delaying procurement increa...
Click here for full text